Internal Asbestos Roof Encapsulation — IT Luggage, Harlow
From failing roof to finished system


The Challenge
The client was overcladding the roof externally and replacing the rooflights. That deals with the outside of the sheets, but leaves the asbestos cement underside exposed above the stock. It needed to be encapsulated internally, across the whole roof.
Duratite surveyed the warehouse first. The roof is asbestos cement sheet on steel purlins carried by steel trusses, with long rooflight strips running along the slopes and protective netting slung below the roof. Eaves height is 5.7 m and the ridge 7.5 m. Below it sits a working warehouse floor, heavily stocked with palletised goods and racking, with lighting and services hung beneath the roof. Anything sprayed overhead had to go onto the sheets and nowhere else.

Project file

Book a free survey and we’ll come back with a fixed price for your own roof.
The Solution — step by step
The system
Bostik Idenden ET-150 is a water-based, low-VOC elastomeric asbestos encapsulation coating. It is designed to seal sound asbestos cement and stop fibre release: the sheets stay where they are — nothing is cut, stripped or taken off site — and the underside is locked under a flexible, durable, water-resistant film. On the manufacturer’s published data it achieves Class 0 to UK Building Regulations at the rated build (two coats at 3.2 m²/L) and BS 476 Part 6 and Part 7 Class 1, with a service temperature range of −29 °C to +80 °C.
Here it was specified in white and spray-applied at 0.5 mm wet film thickness to the underside of the asbestos cement sheets, with the rooflights excluded from the coated area. The overcladding and new rooflights handle the outside of the roof; the encapsulation handles the inside. Together they address both faces of the asbestos cement.
The installation
Duratite Projects Limited carried out the work on a supply-and-fit basis, with materials supplied by Duratite Building Products Limited in 10-litre pails. The programme was planned around weekends so the warehouse could keep trading through the working week:
- Friday afternoon — sheet up. Stock, racking and floor beneath the roof covered for overspray protection before any coating was applied.
- Saturday and Sunday — spray. ET-150 spray-applied to the underside of the sheets from two cherry pickers and one scissor lift working off the warehouse floor.
- Sunday end of day — demobilise. Sheeting and access equipment cleared, ready for the working week.
The work was completed on 27 September 2026.
The Outcome
2,871 m² of asbestos cement underside at IT Luggage’s Harlow warehouse is now sealed under a white elastomeric encapsulation coating — the inside of the roof dealt with alongside the client’s own overcladding and rooflight replacement outside.
The sheets stayed in place, the warehouse was sheeted up for overspray protection, and the work was programmed over weekends so the business kept operating throughout. A 10-year Bostik Idenden ET-150 material warranty and a 10-year Duratite workmanship warranty were issued on completion.
More Duratite case studies
Stockport, Greater Manchester Commercial warehouse — Asbestos Roof EncapsulationAsbestos Roof Encapsulation — Stockport, Greater Manchester
Read the case study
Newfoundland Road, Bristol Commercial — Asbestos Roof EncapsulationAsbestos Roof Encapsulation – Dove Lane, Bristol
Read the case study
Norton St Philip, Bath Retail — Asbestos Roof EncapsulationAsbestos Roof Encapsulation — Flourish Farm Shop, Norton St Philip, Bath
Read the case studyHave a similar asbestos roof encapsulation project?
Tell us about the building and the roof, send a few photos, and we’ll book a free survey and come back with a fixed price — the same process that delivered this project.
Prefer to talk it through?
Speak to a specialist about your project — no obligation, no hard sell.