Asbestos Roof Encapsulation — Stockport, Greater Manchester
From failing roof to finished system


The Challenge
Asbestos cement does not fail all at once. It weathers, loses surface binder and becomes brittle, and at that point every sheet is a liability: it can release fibres into the building below, and it can crack or lift in a storm. This roof had reached that stage.
The building owner needed three things from one piece of work: the asbestos sealed in so it could no longer release fibres, the roof made thermally useful, and the sheets strengthened against wind load — all without the cost and disruption of stripping and replacing 254 m² of roof over an operating warehouse.
Project file

Book a free survey and we’ll come back with a fixed price for your own roof.
The Solution — step by step
Why not simply remove it?
Removal means licensed strip-out, controlled waste, a temporary roof and a closed building. For sheets that are still in place and still shedding water, that is a disproportionate answer. Encapsulating from inside leaves the roof where it is and deals with the hazard at the surface that faces the people underneath.
The system
Closed-cell spray foam was chosen because it does three jobs at once on an asbestos roof:
- Direct adhesion. The foam bonds chemically to the corrugated profile with no mechanical fixings — nothing penetrates or disturbs the asbestos. It cures as one seamless layer that follows every contour and locks the fibres in place.
- Structural strength. The rigid closed-cell structure splints each sheet from beneath and spreads wind load across the whole roof, cutting the risk of sheet failure in high winds.
- Thermal performance. Nexseal LE has a thermal conductivity of 0.027 W/mK. At 75 mm it gives a U-value of 0.35 W/m²K, turning an uninsulated roof into a working part of the building envelope.
Nexseal LE is a closed-cell polyurethane spray foam with a closed-cell content above 90% and a global warming potential of 1. The black Bostik Idenden ET150 topcoat gives the finish the customer asked for and adds UV protection to the foam beneath.
The installation
The work was carried out by British Insulation Services, a Duratite approved installer. The existing sacrificial boarding was carefully removed to expose the underside of the corrugated asbestos cement sheets, and a scissor lift gave safe, stable access across the full roof area.
Nexseal LE was spray-applied at an average thickness of 75 mm directly to the roof sheets. Once cured, the Bostik Idenden ET150 black topcoat was applied over the foam. The whole job took three days, with minimal disruption to the building’s day-to-day use.
The Outcome
All 254 m² of asbestos cement is now sealed under a continuous, fully bonded layer of closed-cell foam. The fibres are locked in, the sheets are stiffened against wind load, and the roof carries a U-value of 0.35 W/m²K where before it had no insulation at all.
The roof went from a deteriorating liability to a performing asset in three days, without a single sheet leaving site. It is a straightforward example of why closed-cell spray foam has become the preferred way to manage an asbestos cement roof: safe, cost-effective and long-lasting, and a credible alternative to full replacement.
More Duratite case studies
Harlow, Essex Commercial warehouse — Internal Asbestos EncapsulationInternal Asbestos Roof Encapsulation — IT Luggage, Harlow
Read the case study
Newfoundland Road, Bristol Commercial — Asbestos Roof EncapsulationAsbestos Roof Encapsulation – Dove Lane, Bristol
Read the case study
Norton St Philip, Bath Retail — Asbestos Roof EncapsulationAsbestos Roof Encapsulation — Flourish Farm Shop, Norton St Philip, Bath
Read the case studyHave a similar asbestos roof encapsulation project?
Tell us about the building and the roof, send a few photos, and we’ll book a free survey and come back with a fixed price — the same process that delivered this project.
Prefer to talk it through?
Speak to a specialist about your project — no obligation, no hard sell.